SEN00593-00 40 Troubleshooting E-5 While the engine is running, the battery charge level caution lamp flashes. 1 16 D65EX, PX, WX-15E0 Symptom of failure • The battery charge level caution lamp flashes. General information • When any abnormality is detected during engine operating, the battery charge level caution lamp flashes. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective alternator (insufficient power genera- tion) aPrepare with starting switch OFF and start the engine to diag- nose. Alternator Engine speed Voltage Terminal R – ground Min.
medium speed (half) 20 – 30 V 2 Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between S04 (female) (9) – alternator terminal R Resis- tance Max. 1 z Between ground and wiring harness between AL/E – GND3 Resis- tance Max. 1 z 3 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF.
Between ground and wiring harness between S04 (female) (9) – alternator R terminal, wiring harness between S04 (female) (9) – ST1 (female) (15), wiring harness among S04 (female) (9) – G01 (female) (28) – ST3 (female) (4), and wiring harness among S04 (female) (9) – starting switch 260 (BR) – SW (battery relay) Resis- tance Min. 1 Mz 4 Defective monitor panel aPrepare with starting switch OFF and diagnose with starting switch ON. S04 Engine speed Voltage Between (9) – ground Min. medium speed (half) 20 – 30 V