40 Troubleshooting SEN00593-00 E-4 When the starting switch is turned on, the monitor panel completely remains lighted and does not go out. 1 D65EX, PX, WX-15E0 15 Symptom of failure • When the starting switch is turned ON, the monitor panel completely remains lighted and does not go out. General information • When the starting switch is turned ON, the gear speed indicator, multi-information section, gauge section, and lamp section light up for approximately 2 sec. and then go out. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective monitor panel Since this is an internal defect, it cannot be diagnosed.