SEN00593-00 40 Troubleshooting E-11 Fuel gauge does not indicate properly. 1 Circuit diagram related to fuel level sensor 30 D65EX, PX, WX-15E0 Symptom of Fu failure el gauge does not indicate properly. General • information The input state (voltage signal) from the fuel level sensor can be checked in monitoring mode. (Code: 04200 Fuel level sensor voltage) 1 2 Possible causes and the standard values when normal 3 4 5 Cause Standard value when normal and remarks for troubleshooting Defective fuel level sensor (Internal disconnection and short circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF.
423 (male ) Fuel level Resistance Between (1) ground – (2) Full Empty Approx. 4 z Approx. 85 z Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between S04 (female) (10) – 423 (female) (1) Resis- tance Max. 1 z Wiring harness among 423 (female) (2) – S03 (female) (3), (4) – ground Resis- tance Max. 1 z Defective grounding of wiring harness (a contact with GND circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between S04 (female) (10) – 423 (female) (1) Resis- tance Min.
1 Mz Hot short of wiring harness (a contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harness between S04 (female) (10) – 423 (female) (1) Voltage Max. 1 V Between ground and wiring harness between 423 (female) (2) – S03 (female) (3) (4) Voltage Max. 1 V Defective monitor panel Since this is an internal defect, it cannot be diagnosed.