Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-14 THE WARNING LAMP DOES NOT FLASH OR DOES NOT GO OUT.

40 Troubleshooting SEN00593-00 E-12 Gear speed and engine speed are not indicated properly. 1 E-13 The preset mode service meter does not indicate normally. 1 E-14 The warning lamp does not flash or does not go out. 1 D65EX, PX, WX-15E0 31 Symptom of failure • Gear speed and engine speed are not indicated properly. General information • Signals of gear speed and engine speed are sent and received through communication by steering and transmission controller and engine controller. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective monitor panel Since this is an internal defect, it cannot be diagnosed.

Symptom of failure (1) During engine operation, the service meter does not advance. General information • The service meter measures time while the monitor panel is receiving engine drive signals (alternator signals). • The display data of the preset mode and service meter are sent and received through communica- tion by the steering and transmission controller.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective alternator signals system When the battery charge level caution lamp flashes during engine operation, carry out the troubleshooting of “E-5 While the engine is operating, battery charge level caution flashes”. 2 Defective monitor panel (Gauge or lamp module) Since this is an internal defect, it cannot be diagnosed. Symptom of failure (2) Shift mode and service meter are not displayed at all. General information • The display data are sent and received through communication by the steering and transmission controller.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective monitor panel Since this is an internal defect, it cannot be diagnosed. Symptom of failure • The warning lamp does not flash or does not go out. General information Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective monitor panel Since this is an internal defect, it cannot be diagnosed.