Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-15 THE ALARM BUZZER DOES NOT SOUND OR DOES NOT STOP.

SEN00593-00 40 Troubleshooting E-15 The alarm buzzer does not sound or does not stop. 1 32 D65EX, PX, WX-15E0 Symptom of failure • The alarm buzzer does not sound or does not stop. General information • When a short circuit occurs in the alarm buzzer system, the failure code [DV00KB] is displayed but no other failure codes are displayed. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective starting switch (internal disconnection) aPrepare with the starting switch OFF, then carry out troubleshoot- ing without turning the starting switch ON. Starting switch Switch position Resistance Between (B) – 270 (ACC) OFF Min.

1 Mz ON(ACC) Max. 1 z 2 Defective alarm buzzer (Internal disconnection and short circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. 217 (male) Continuity Between (2) – (1) Continue Between (1), (2) – ground No continuity 3 Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between S03 (female) (18) – 217 (female) (1) Resis- tance Max. 1 z Wiring harness between 217 (female) (2) – starting switch 270 (ACC) Resis- tance Max.

1 z 4 Defective grounding of wiring harness (a contact with GND circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground wiring harness between starting switch 270 (ACC) – 271 (female) (2) Resis- tance Min. 1 Mz Between ground and wiring harness between 217 (female) (1) – S03 (female) (18) Resis- tance Min. 1 Mz 5 Defective monitor panel (Gauge or lamp module) aPrepare with starting switch OFF and diagnose with starting switch ON. S03 Alarm buzzer Voltage Between (18) – ground When stopping 20 – 30 V When turned ON (sounding) Max. 3 V