Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-24 THE HORN DOES NOT SOUND OR DOES NOT STOP.

40 Troubleshooting SEN00593-00 E-24 The horn does not sound or does not stop. 1 Circuit diagram related to horn D65EX, PX, WX-15E0 51 Symptom of failure • The horn does not sound or does not stop. General information Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Disconnection of fuse (FS1-7) If fuse is burnt, it is highly possible that a defective harness ground- ing, etc. has occurred in the circuit. 2 Defective horn switch (Internal short circuit and dis- connection) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Terminal (switch) Horn switch Resistance 265 – 266 OFF Min. 1 Mz ON Max.

1 z 3 Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between FS1-7 – 266 Resis- tance Max. 1 z Wiring harness between 265 – 205 (female) (1) Resis- tance Max. 1 z 4 Defective grounding of wiring harness (a contact with GND circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between ground and wiring harness between FS1-7 – 266 Resis- tance Min. 1 Mz Between ground and wiring harness between 265 – 205 (female) (1) Resis- tance Min.

1 Mz 5 Hot short of wiring harness (a contact with 24 V circuit) aPrepare with starting switch OFF and diagnose with starting switch ON. Between ground and wiring harness between 265 – 205 (female) (1) Voltage Max. 1 V 6 Defective horn (Internal defect) When Causes 1 to 5 are not applicable, the horn is supposed to be defective.