SEN00593-00 40 Troubleshooting E-25 Malfunction of wipers 1 52 D65EX, PX, WX-15E0 Symptom of failure (1) The front wiper does not operate. (Continuous operation is defective.) General information • When only the front wiper is defective • If fuse (5) in the cab is blown, intermittent operation of the all wipers becomes defective. • If any wiper does not operate, check fusible link (FL1). • Diagnose with intermittent switch OFF and with wiper switch ON. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective fusible link (FL1) If the fusible link is burnout, the circuit probably has a grounding fault, etc.
2 Defective fuse (5) in cab Since fuse (5) in the cab is used for the front wiper circuit and inter- mittent switch circuit, either circuit of those two probably have a grounding fault, etc. 3 Defective front wiper motor aPrepare with starting switch OFF and diagnose with starting switch ON. Between CN23 (6) – ground Voltage 20 – 30 V aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between CN23 (female) (1) – ground Resis- tance Max. 1 z 4 Defective front wiper switch aPrepare with starting switch OFF and diagnose with starting switch still OFF. CN14 (male) Position of switch Resistance Between (3) – (4) ON Max. 1 z OFF Min.
1 Mz 5 Defective front wiper inter- mittent selector relay • If the problem is eliminated by replacing the relay (CN27), (CN31) or (CN33) with another one, the relay is defective. aPrepare with starting switch OFF and diagnose with starting switch ON. Between CN29 (3) – ground Voltage 20 – 30 V Between CN29 (6) – ground Voltage 20 – 30 V Between CN29 (1) – ground Voltage Max. 1 V 6 Defective front wiper inter- mittent relay • If the problem is eliminated by replacing the relay (CN26), (CN30) or (CN32) with another one, the relay is defective. aPrepare with starting switch OFF and diagnose with starting switch ON.
Between CN28 (4) – ground Voltage 20 – 30 V Between CN28 (3) – ground Voltage 20 – 30 V Between CN28 (5) – ground Voltage 20 – 30 V