40 Troubleshooting SEN00593-00 D65EX, PX, WX-15E0 53 Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 7 Disconnection or short circuit with ground in wiring harness (Disconnection in wiring or defective contact of connec- tors or contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between CN14 (female) (4) – CN29 (female) (3) Resis- tance Max. 1 z Between ground and wiring harness between CN14 (female) (4) – CN29 (female) (3) Resis- tance Min. 1 Mz Wiring harness between CN29 (female) (6) – CN28 (female) (4) Resis- tance Max.
1 z Between ground and wiring harness between CN29 (female) (6) – CN28 (female) (4) Resis- tance Min. 1 Mz Wiring harnesses between fuse (5) – CN14 (female) (2) (3) and CN23 (female) (3) – CN28 (female) (3) Resis- tance Max. 1 z Between ground and wiring harnesses between fuse (5) – CN14 (female) (2) (3) and CN23 (female) (3) – CN28 (female) (3) Resis- tance Min. 1 Mz Wiring harness between CN28 (female) (5) – CN23 (female) (6) Resis- tance Max. 1 z Between ground and wiring harness between CN28 (female) (5) – CN23 (female) (6) Resis- tance Min. 1 Mz Wiring harness between CN28 (female) (6) – ground Resis- tance Max. 1 z Wiring harness between CN23 (female) (1) – ground Resis- tance Max. 1 z