SEN00593-00 40 Troubleshooting 54 D65EX, PX, WX-15E0 Symptom of failure (2) Front wiper malfunctions in the intermittent mode. General information • When the ordinary operation is normal. • When carrying out the troubleshooting, turn the wiper switch and intermittent switch ON. • The wiper stops for about 5 seconds after a single wiping operation. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective intermittent switch • If the ordinary operation is normal and the other wiper also mal- functions in the intermittent mode, the intermittent switch is prob- ably defective.
aPrepare with starting switch OFF and diagnose with starting switch still OFF. CN11 (male) Position of switch Resistance Between (1) – (2) ON Max. 1 z OFF Min. 1 Mz 2 Defective front wiper inter- mittent selector relay • If the problem is eliminated by replacing the relay (CN27), (CN31) or (CN33) with another one, the relay is defective. aPrepare with starting switch OFF and diagnose with starting switch ON. Between CN29 (1) – ground Voltage 20 – 30 V Between CN29 (5) – ground Voltage 20 – 30 V 3 Defective front wiper inter- mittent relay • If the problem is eliminated by replacing the relay (CN26), (CN30) or (CN32) with another one, the relay is defective.
aPrepare with starting switch OFF and diagnose with starting switch ON. Between CN28 (2) – ground Voltage 20 – 30 V 4 Disconnection or short circuit with ground in wiring harness (Disconnection in wiring or defective contact of connec- tors or contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between CN11 (female) (2) – CN29 (female) (1) Resis- tance Max. 1 z Between ground and wiring harness between CN11 (female) (2) – CN29 (female) (1) Resis- tance Min. 1 Mz Wiring harness between CN29 (female) (5) – CN28 (female) (2) Resis- tance Max.
1 z Between ground and wiring harness between CN29 (female) (5) – CN28 (female) (2) Resis- tance Min. 1 Mz Wiring harness between CN29 (female) (2) – ground Resis- tance Max. 1 z