SEN00593-00 40 Troubleshooting 60 D65EX, PX, WX-15E0 Symptom of failure (5) The right door wiper does not operate. (Continuous operation is defective.) General information • When only the right door wiper is defective (If fuse (6) in the cab is blown, the left door wiper does not operate either.) • If any wiper does not operate, check fusible link (FL1). • When carrying out the troubleshooting, turn the intermittent switch OFF and turn the wiper switch ON. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective fusible link (FL1) If the fusible link is burnout, the circuit probably has a grounding fault, etc.
2 Defective fuse (6) in cab Since fuse (6) in the cab is used for the right and left wiper system, either circuit of those two probably has a grounding fault, etc. 3 Defective right door wiper motor aPrepare with starting switch OFF and diagnose with starting switch ON. Between connector (3) just before motor – ground Voltage 20 – 30 V aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between connector (1) just before motor – ground Resis- tance Max. 1 z 4 Defective right door wiper switch aPrepare with starting switch OFF and diagnose with starting switch still OFF. CN13 (male) Position of switch Resistance Between (3) – (4) ON Max. 1 z OFF Min.
1 Mz 5 Defective right door wiper intermittent selector relay • If the problem is eliminated by replacing the relay (CN27), (CN29) or (CN33) with another one, the relay is defective. aPrepare with starting switch OFF and diagnose with starting switch ON. Between CN31 (3) – ground Voltage 20 – 30 V Between CN31 (6) – ground Voltage 20 – 30 V Between CN31 (1) – ground Voltage Max. 1 V 6 Defective right door wiper intermittent relay • If the problem is eliminated by replacing the relay (CN26), (CN28) or (CN32) with another one, the relay is defective. aPrepare with starting switch OFF and diagnose with starting switch ON.
Between CN30 (4) – ground Voltage 20 – 30 V Between CN30 (3) – ground Voltage 20 – 30 V Between CN30 (5) – ground Voltage 20 – 30 V