40 Troubleshooting SEN00593-00 D65EX, PX, WX-15E0 61 Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 7 Disconnection or short circuit with ground in wiring harness (Disconnection in wiring or defective contact of connec- tors or contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between CN13 (female) (4) – CN31 (female) (3) Resis- tance Max. 1 z Between ground and wiring harness between CN13 (female) (4) – CN31 (female) (3) Resis- tance Min. 1 Mz Wiring harness between CN31 (female) (6) – CN30 (female) (4) Resis- tance Max.
1 z Between ground and wiring harness between CN31 (female) (6) – CN30 (female) (4) Resis- tance Min. 1 Mz Wiring harnesses among fuse (6) – CN13 (female) (2) (3) – CN17 (4) – connector just before motor (female) (4) – CN13 (female) (2) (3) Resis- tance Max. 1 z Between ground and wiring harnesses among fuse (6) – CN13 (female) (2) (3) – CN17 (4) – connector just before motor (female) (4) – CN13 (female) (2) (3) Resis- tance Min. 1 Mz Wiring harness between fuse (6) – CN30 (female) (3) Resis- tance Max. 1 z Between ground and wiring harness between fuse (6) – CN30 (female) (3) Resis- tance Min.
1 Mz Wiring harness among connector just before motor (female) (3) – CN17 (3) – CN30 (female) (5) Resis- tance Max. 1 z Between ground and wiring harness between connector just before motor (female) (3) – CN17 (3) – CN30 (female)(5) Resis- tance Min. 1 Mz Wiring harness between CN30 (female) (6) – ground Resis- tance Max. 1 z Wiring harness among connector just before motor (female) (1) – CN17(1) – ground Resis- tance Max. 1 z