Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-26 WASHER DOES NOT SPRAY WATER

40 Troubleshooting SEN00593-00 * For the electric diagram of each system, see Symptom of failure (1). D65EX, PX, WX-15E0 71 Symptom of failure (3) Left door washer does not spray water General information • When the left door wiper operates normally (If the wiper does not operate either, carry out troubleshooting in “E-25 (7) The left wiper does not operate.” first.) • Since the left door wiper switch and right door wiper switch use fuse (6) jointly, if fuse (6) is blown, both wipers do not operate.

Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective left door washer motor aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between 9 (female) (1) – ground Resis- tance Max. 1 z aPrepare with starting switch OFF and diagnose with starting switch ON. (switch position: W/I) Between 9 (2) – ground Voltage 20 – 30 V 2 Defective left door wiper switch aPrepare with starting switch OFF and diagnose with starting switch still OFF. CN15 (female) Position of switch Resistance Between (2) – (1) W/I or W/II Max. 1 z OFF Min.

1 Mz 3 Disconnection or short circuit with ground in wiring harness (Disconnection in wiring or defective contact of connec- tors or contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between fuse (6) – CN15 (female) (2) Resis- tance Max. 1 z Between ground and wiring harness between fuse (6) – CN15 (female) (2) Resis- tance Min. 1 Mz Wiring harness between CN15 (female) (1) – 19 (1) – 13 (1) – 9 (female) (2) Resis- tance Max. 1 z Between ground and wiring harness among CN15 (female) (1) – 19 (1) – 13 (1) – 9 (female) (2) Resis- tance Min. 1 Mz Wiring harness between 9 (female) (1) – ground Resis- tance Max. 1 z