Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-27 THE AIR CONDITIONER DOES NOT OPERATE

SEN00593-00 40 Troubleshooting E-27 The air conditioner does not operate 1 74 D65EX, PX, WX-15E0 Symptom of failure • Air does not blow out General information Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective circuit breaker (CB2) When the circuit breaker is cut off, a defective grounding may have possibly occurred in the circuit. 2 Defective blower main relay (coil side) aPrepare with starting switch OFF and diagnose with starting switch still OFF.

CN-R1 (male) Resistance Between (1) – (2) 240 ± 40 z 3 Defective blower main relay (contact side) aPrepare with starting switch OFF and diagnose with starting switch ON. CN-R1 Voltage Between (8C) – ground 20 – 30 V 4 Defective blower Hi relay (coil side) aPrepare with starting switch OFF and diagnose with starting switch still OFF. CN-R2 (male) Resistance Between (1) – (2) 240 ± 40 z 5 Defective blower Hi relay (contact side) aPrepare with starting switch OFF and diagnose with starting switch ON. It is normal if the motor rotates with the starting switch and the blower Hi switch turned ON.

6 Defective blower Mi1 relay (coil side) aPrepare with starting switch OFF and diagnose with starting switch still OFF. CN-R3 (male) Resistance Between (1) – (2) 240 ± 40 z 7 Defective blower Mi1 relay (contact side) aPrepare with starting switch OFF and diagnose with starting switch ON. It is normal if the motor rotates with the starting switch and the blower Mi switch turned ON. 8 Defective blower Mi2 relay (coil side) aPrepare with starting switch OFF and diagnose with starting switch still OFF. CN-R4 (male) Resistance Between (1) – (2) 240 ± 40 z 9 Defective blower Mi2 relay (contact side) aPrepare with starting switch OFF and diagnose with starting switch ON.

It is normal if the motor rotates with the starting switch and the blower Lo switch turned ON. 10 Defective blower motor aPrepare with starting switch OFF and diagnose with starting switch ON. It is normal if the motor rotates with the starting switch and the blower Lo switch turned ON.