40 Troubleshooting SEN00593-00 D65EX, PX, WX-15E0 75 Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 11 Disconnection or defective grounding in wiring harness (Disconnection in wiring or defective contact of connec- tors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness among CN-R4 (female) (14C) – AC1 (female) (14A) – CN-R (female) (S141) – CN-R2 (female) (14E) – CN-R3 (female) (14N) – ground Resis- tance Max. 1 z Wiring harness between CN-B (female) (11B) – CN-R1(female) (11A) Resis- tance Max.
1 z Wiring harness among CN-B (female) (12A) – CN-R2 (female) (12B) – CN-R (female) (12C) Resis- tance Max. 1 z Wiring harness among CB2 out – AC1 (female) (1A) – CN-R1 (female) (1D) – CN- R2 (female) (1E) – CN-R3 (female) (1N) – CN-R4 (female) (1I) Resis- tance Max. 1 z Wiring harness between CN-R1 (female) (2B) – AC1 (female) (2A) Resis- tance Max. 1 z Wiring harness between CN-R3 (female) (3B) – AC1 (female) (3A) Resis- tance Max. 1 z Wiring harness between CN-R2 (female) (5B) – AC1 (female) (5A) Resis- tance Max. 1 z Wiring harness between CN-R4 (female) (4B) – AC1 (female) (4A) Resis- tance Max.
1 z 12 Defective control panel Control panel is possibly defective if no problem is found in causes 1-11. 13 Symptom of failure is incorrect. When the cause cannot be identified, the Symptom of failure may be incorrect. Carry out the troubleshooting of “It does not get cool.”