Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-27 THE AIR CONDITIONER DOES NOT OPERATE

SEN00593-00 40 Troubleshooting 76 D65EX, PX, WX-15E0 Symptom of failure • It does not get cool. General information Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective pressure switch aPrepare with starting switch OFF and diagnose with starting switch ON. CN-P Blower switch Voltage Between (6B) – ground ON 20 – 30 V 2 Defective compressor clutch relay (coil side) aPrepare with starting switch OFF and diagnose with starting switch still OFF.

CN-R5 (male) Resistance Between (1) – (2) 240 ± 40 z 3 Defective compressor clutch relay (contact side) aPrepare with starting switch OFF and diagnose starting switch and air conditioner switch ON. CN-R5 Voltage Between (18A) – ground 20 – 30 V 4 Defective thermistor aPrepare with starting switch OFF and diagnose with starting switch still OFF. CN-T (male) Resistance Between (1) – (2) Max. 3,500 z 5 Defective blower resistor aPrepare with starting switch OFF and diagnose with starting switch still OFF. Blower resistor Resistance Between terminals 2.8 z ± 5% 6 Defective compressor mag- net clutch a Start the engine to diagnose.

The compressor magnet clutch is supposed to be defective, so inspect itself. 7 Defective compressor a Start the engine to diagnose. Since the compressor is supposed to be defective, inspect the com- pressor. 8 Defective diode (internal short circuit) Diagnose diode ACG (male). • See the “Inspection procedure of diode” in the “Testing and adjusting” section. 9 Disconnection in wiring harness (Disconnection in wiring or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF.

Wiring harness among CB2 out – AC1 (female) (1A) – CN-R1 (female) (1D) – CN- R2 (female) (1E) – CN-R3 (female) (1N) – CN-R4 (female) (1I) – CN-R5 (female) (1K) Resis- tance Max. 1 z Wiring harness among CN-T (female) (13B) – AC1 (female) (13A) – CN-W (female) (13C) Resis- tance Max. 1 z Wiring harness between CN-T (female) (9B) – AC1 (female) (9A) Resis- tance Max. 1 z Wiring harness between CN-P (female) (7B) – CN-R5 (female) (7A) Resis- tance Max. 1 z Wiring harness between CN-P (female) (6B) – AC1 (female) (6A) Resis- tance Max. 1 z 10 Defective control panel Control panel is possibly defective if no problem is found in causes 1-9.