SEN00593-00 40 Troubleshooting E-28 KOMTRAX system does not operate normally. 1 78 D65EX, PX, WX-15E0 Symptom of failure • KOMTRAX system does not operate normally. General information • If KOMTRAX system administrator makes request for checking system on machine side for trouble, carry out the following troubleshooting. • Even if KOMTRAX system has a trouble, it does not paticularly appear on machine. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective specification setting Check the code 0021: KOMTRAX specification setting in adjust- ment mode and set to “ACTIV”.
2 Defective electric power supply a Diagnose with the starting switch OFF. LED (1) Normal condition LED-A1 ON aPrepare with starting switch OFF and diagnose with starting switch still OFF. G01 Signal Voltage Between (39) (40) – (37) (38) Constant power source 20 – 30 V 3 Defective communication environment aDiagnose starting switch ON. LED (2) Normal condition LED-A2 ON 4 Defective starting switch ACC signal and alternator R signal a Diagnose with starting switch ON and with the engine started. LED (6) Normal condition LED-C1 ON aPrepare with starting switch OFF and start the engine to diag- nose.
G01 Signal Voltage Between (36) – (37) (38) Starting switch ACC 20 – 30 V Between (28) – (37) (38) Alternator R 20 – 30 V 5 Defective starting switch C signal aPrepare with starting switch OFF and diagnose with starting switch ON. G01 Signal Voltage Between (27) – (37) (38) Starting switch C 20 – 30 V 6 Defective CAN connecting condition aDiagnose starting switch ON. LED (9) Normal condition LED-C4 ON aPrepare with starting switch OFF and diagnose with starting switch still OFF. G01 (female) Signal Resistance Between (8) – (7) CAN 40 – 80 z 7 Number of mails not yet sent a Diagnose starting switch ON. LED (12) Normal condition 7 segments 0 – 9