Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-28 KOMTRAX SYSTEM DOES NOT OPERATE NORMALLY.

40 Troubleshooting SEN00593-00 Lamp display section of KOMTRAX terminal G01 connector LED for communication module 1. LED-A1 (power indicator lamp) 2. LED-A2 (within communication range lamp) 3. LED-A3 (on communicating lamp) 4. LED-A4 (internal transmitting lamp) 5. LED-A (internal reception lamp) CPU LED 6. LED-C1 (R signal and ACC signal status) 7. LED-C2 (starting output status) 8. LED-C3 (S-NET, C signal status) 9. LED-C4 (CAN status) 10. LED-C5 (download writing condition) 11. LED-C6 (download writing condition) 7 segments and dot for CPU 12. 7 segments (number of mails not yet sent) 13.

Dot (GPS positioning in progress) D65EX, PX, WX-15E0 79 Possible causes and the D standard values 8 s when normal Cause Standard value when normal and remarks for troubleshooting efective GPS positioning tatus I t a Diagnose starting switch ON. LED (13) Normal condition Dot ON t may take more than 1 minute from turning on the starting switch to he completion of positioning even in an outdoor place where radio wave can reach.