40 Troubleshooting SEN00595-00 *1: Failure code of code display [CA559] and [CA2249] *2:
Failure code of code display [CA2265] and [CA2266] D65EX, PX, WX-15E0 9 c) Exhaust smoke comes out but engine does not start (Fuel is being injected) General causes why exhaust smoke comes out but engine does not start • Lack of rotating force due to defective electrical system • Insufficient supply of fuel • Insufficient intake of air • Improper selection of fuel Cause Clogged air cleaner element Worn dynamic valve system (valve, rocker lever, etc.) Worn piston ring, cylinder liner Improper fuel used Clogged air breather hole in fuel tank cap Leakage, clogging, air in fuel system Clogged fuel filter Stuck, seized fuel supply pump plunger Defective electric lift pump Clogged injector, defective spray Defective or deteriorated battery Defective coolant temperature sensor, defective wiring harness Defective intake air hearter system Questions Check items Confirm recent repair history Degree of use of machine Operated for long period E E E Suddenly failed to start w w Q Non-specified fuel is being used w Q Q Replacement of filters has not been carried out according to Operation & Maintenance Manual w w Engine oil must be added more frequently w Preheating monitor does not work noramlly during preheating or in low temperatures (when monitor is installed) w Dust indicator lamp is red (when indicator is installed) w Air breather hole in fuel tank cap is clogged Q Rust and water are found when fuel tank is drained w When fuel filter is removed, there is no fuel in filter w Q There is a leakage from fuel piping w Starting motor cranks engine slowly w When engine is cranked, abnormal noise is heard from around cylinder head w When engine is cranked with starting motor No fuel comes out even when fuel filter air bleed plug is removed Q w Q When hose at collection portion for spill flow from fuel injector is dis- connected, spill flow is small w When exhaust manifold is toutched immediately after starting engine, temperature of some cyl- inders is low w Troubleshooting Check air cleaner directly q Check dynamic valve system directly q When compression pressure is measured, it is found to be low q When air is bled from fuel line, air comes out q Check fuel filter directly q Carry out troubleshooting for code display “Supply pump pressure no signal (*1)“ q Carry out troubleshooting for code display “Defective electric lift pump (*2)“ q Possible to start in reduced cylinder mode q When specific gravity of electrolyte or voltage of battery is measured, it is found to be low.
q Defective coolant temperature gauge display (when coolant temerature gauge is installed) q Intake air heater mount does not become warm during preheating q Action Clean Replace Replace Replace Clean Correct Replace Replace Replace Replace Replace Replace Replace