CLAAS LEXION 500 series (520, 570) — Module A66 - GPS pilot module (GPB)

Key to diagram: Coordinates A25 Sieve adjustment module.................................................... 2-i-20 DS Diagnosis plug (63-pin) VIA................................................. 3-i-20 K41 Upper sieve adjustment relay (close).................................. 4-i-20 K42 Upper sieve adjustment relay (open) .................................. 4-i-20 K43 Lower sieve adjustment relay (close).................................. 4-i-20 K44 Lower sieve adjustment relay (open) .................................. 4-i-20 K49 Road travel main relay ........................................................ 4-i-20 M12 Upper sieve adjustment motor ...........................................

6-q-18 M23 Lower sieve adjustment motor ........................................... 7-q-18 R37 Upper sieve adjustment potentiometer .............................. 6-q-18 R38 Lower sieve adjustment potentiometer .............................. 7-q-18 U6 Upper sieve adjustment switch............................................5-r-20 U7 Lower sieve adjustment switch............................................5-r-20 95±10 Ω (Pin 86/1 – 85/2) (Pin 87a/4 – 30/3) (Pin 87/5 – 30/3) Measured value table: Item Component Measured value Remark R37 R38 Potentiometer 0.5 - 5.2 K Ω 0.45 - 4.55 V Coil Signal M12 M23 Electric motor 2.5 A max.

Remote control relay 15 A 30 A K41 K42 K43 K44 Electric System LEXION 500 TIC 11a-2 Lex-e-11a 03/05 11a Sieve adjustment Item Component Measured value Remark K41 K42 K43 K44 Remote control relay 15 A 30 A 95±10 Ω (Pin 86/1 – 85/2) (Pin 87a/4 – 30/3) (Pin 87/5 – 30/3) M12 M23 Electric motor 2.5 A max. R37 R38 Potentiometer 0.5 - 5.2 KΩ 0.45 - 4.55 V Coil Signal