CLAAS LEXION 500 series (520, 570) — 17s - Front attachment drive, reverser drive, front attachment quick stop, Montana 570-520 - with external MONTANA control unit (up to serial no. 582 00051, 581 00026; 580 00028)

TIC LEXION Montana 570-520 Electric System Description of function: 1/2 Front attachment circuit Relay K49 must be actuated by the road travel circuit and the threshing mechanism must be actuated by relay K14 as pre-conditions for the front attachment drive. The threshing mechanism ON signal is read in by the fieldwork computer module (A10) – Circuit diagram 7a of standard machine. Front attachment ON Note: The front attachment circuit depends on the closed seat contact switch (Z5). When actuating the front attachment ON/OFF switch (S95), a voltage is connected to the fieldwork computer module (A10) as a signal.

In order to ensure smooth start-up of the front attachment and to avoid strain on the drive components, the fieldwork computer module (A10) actuates the solenoid coil (Y88) in a modulated way (PWM) – Front attachment ON. Front attachment OFF When actuating the STOP pushbutton (S54) on the multi-function handle to the first stage, earth is connected as a signal to the fieldwork computer module (A10). The fieldwork computer module (A10) cuts the power supply to the solenoid coil (Y88) – Front attachment OFF.

Front attachment quick stop When actuating the STOP pushbutton (S54) on the multi-function handle to the second stage, the front attachment quick stop solenoid coil (Y101) is actuated via relay K15 in addition to the "Front attachment OFF" function. The same applies to the actuation of the front attachment ON/OFF switch (S95) in the operating panel. When S95 is actuated beyond the spring- centred centre position, the voltage signal to the fieldwork computer module (A10) is interrupted (front attachment OFF) and at the same time, K15 is actuated (quick stop ON).

The master valve (Y77) is also actuated via the diode PCB (DO) in parallel with the solenoid coil (Y101) because this function requires that pressure is built up in the system. 03/05 Lex-e-17s 17s-3