CLAAS LEXION 500 series (520, 570) — 17s - Front attachment drive, reverser drive, front attachment quick stop, Montana 570-520 - with external MONTANA control unit (up to serial no. 582 00051, 581 00026; 580 00028)

Electric System LEXION Montana 570-520 TIC Description of function: 2/2 Reverse front attachment The front attachment must not be engaged as a pre-condition for the reversing function. The speed monitor module (A12) connects voltage to the reverse switch (S57) as an additional safety feature only after the feeder housing speed sensor (B12) stops transmitting a signal for approx. 2 seconds. If these pre-conditions are met, voltage is connected from the speed monitor module (A12) to solenoid coil (Y86) via the reverse switch (S57) - Front attachment reverse function.

The master valve (Y77) is actuated via the diode PCB (DO) in parallel with the solenoid coil (Y86) because this function requires that pressure is built up in the system. Important! When reversing is activated, a signal is connected to the reel controller module (A16) which makes the reel drive variable-displacement pump swing to maximum delivery, depending on the front attachment identification – Circuit diagram 22 of standard machine. Seat contact circuit After leaving the operator's seat, all circuits depending on the seat contact are interrupted after approx. 5 seconds. 17s-4 Lex-e-17s 03/05