CLAAS LEXION 500 series (520, 570) — 19c - Straw chopper, radial spreader with chaff spreader

TIC LEXION 500 Electric System Description of function: 1/2 Radial spreader in working or swathing position With the road travel circuit unlocked and only with the threshing mechanism disengaged, switch (U13) is supplied with power. The position control of the radial spreader requires that another pre- condition is fulfilled: No signal from the straw chopper speed sensor B28 (uni-spreader) is identified on the CAN bus for at least 2 seconds. When the radial spreader is in transport position, it moves to the swathing position first after switch U13 is actuated.

To achieve this, the radial spreader module (A51) actuates solenoid coil Y184 until it reaches its end position - actual value switch Z59 is closed on pins 1 and 4. If switch U13 is actuated one more time after the swathing position is identified - actual value switch Z59 is closed on pins 1 and 4 - the radial spreader module (A51) actuates the solenoid coil Y185 until the working position is identified - actual value switch Z58 is closed on pins 1 and 4. When switch U13 is pressed repeatedly, the radial spreader again changes between working and swathing position - toggle function.

The master valve (Y77) is also actuated via the diode PCB (DO) in parallel with the solenoid coils (Y184/Y185) because this function requires that pressure is built up in the system. Radial spreader in transport position With the road travel circuit unlocked and only with the threshing mechanism disengaged, switch (U14) is supplied with power. The position control of the radial spreader requires that another pre- condition is fulfilled: No signal from the straw chopper speed sensor B28 (uni-spreader) is identified on the CAN bus for at least 2 seconds.

When the straw chopper switch is actuated while in rest position (U14 = radial spreader in transport position), the radial spreader moves to transport position. To achieve this, the radial spreader module actuates the solenoid coils Y185 and Y174. The actual value switches Z58 and Z59 are not actuated any more (closed on pins 2 and 3). When the correct transport position is reached, the actual value switch Z60 is actuated (closed on pin 1 and 4). The master valve (Y77) is also actuated via the diode PCB (DO) in parallel with the solenoid coil (Y185) because this function requires that pressure is built up in the system. 03/05 Lex-e-19c 19c-3