CLAAS LEXION 500 series (520, 570) — 19c - Straw chopper, radial spreader with chaff spreader

Electric System LEXION 500 TIC Description of function: 2/2 Straw chopper / radial spreader warning When the actual value switches Z58 and Z59 are not actuated, the terminal A30 gives a warning when the threshing mechanism is engaged. Straw chopper circuit The relay K49 must be actuated by unlocking the road travel switch (S52) and the limit switch (Z58) must be closed in working position as pre- conditions for the straw chopper drive. The threshing mechanism clutch switch (S25) controls relay K14 and thus activates the power supply for solenoid coil (Y21) of the threshing mechanism clutch (see also diagram 4).

When the actual value switch (Z58) is actuated, the solenoid coil (Y76) for the straw chopper drive is also actuated in the working position of the straw chopper. Straw chopper speed monitoring When the straw chopper is activated, the speed monitor module (A12) receives the start signal for monitoring the straw chopper speed from sensor (B28). 19c-4 Lex-e-19c 03/05