Key to diagram: Coordinates B123 Hydraulic oil temperature sensor........................................ 3-p-19 B127 Ground drive hydraulics metal detector sensor.................. 7-q-18 DI Warning device diode PCB ................................................. 4-i-20 H20 Rubber track tension signal light ........................................ 3-h-17 X13 3D / rear axle connector..................................................... 6-p-16 K49 Road travel main relay ........................................................ 4-i-20 K52 Power supply relay ..............................................................
4-i-20 K56 Electronic unit plus relay ..................................................... 4-i-20 K67 Spare relay (rubber track tension)....................................... 4-i-20 Z9a Brake lining wear actual value switch ................................. 7-j-18 Z9b Brake lining wear actual value switch ................................. 7-j-18 Z12 Parking brake actual value switch...................................... 5-g-19 Z19 Hydraulic oil level actual value switch (min.)...................... 3-p-19 Z20 Hydraulic oil temperature actual value switch.................... 3-p-19 Z36 Left rubber track tension actual value switch ......................
7-i-21 Z37 Right rubber track tension actual value switch.................... 7-i-16 Z38 Left steering position actual value switch........................... 7-q-20 Z39 Right steering position actual value switch ........................7-q-16 Z46 Low-pressure hydraulics/ground drive oil pressure actual value switch .............................................................3-p-19 Z61 Straw jam warning actual value switch .............................. 3-s-18 Z78 Ground drive filter actual value switch ............................... 3-o-19 a - Switch or sensor, depending on equipment fitted Note:
The rubber track tension actual value switches (Z36/Z37) are shown in their unactuated state. If the rubber track tension is correct, both switches are closed and therefore relay K67 is actuated when the machine is running. Z78 Pressure switch > 1250 Ω Ω Not actuated Actuated Item Component Measured value Remark B123 Sensor 12 V Signal = Earth (Pin 1-3) (Pin 2) Measured value table: Electric System LEXION 500 TIC 26a-2 Lex-e-26a 26a Machine monitor Item Component Measured value Remark B123 Sensor 12 V Signal = Earth (Pin 1-3) (Pin 2) Z78 Pressure switch > 1250 Ω Not actuated Actuated