TIC LEXION 500 Electric System Description of function: Hydraulic oil level warning (min.) If the diesel engine is not started, the terminal (A30) recognizes an earth signal on pin 15 as the signal of the float switch (Z19) and displays the filling level alarm message. At the same time, the earth signal is sent to the pulse generator K57 through the diode PCB (DI). Low-pressure hydraulics/ground drive oil pressure warning If the diesel engine is started, the terminal (A30) recognizes an earth signal on pin 15 as the signal of the oil pressure switch (Z46) and displays the oil pressure alarm message.

At the same time, the earth signal is sent to the pulse generator K57 through the diode PCB (DI). Hydraulic oil temperature warning The earth signal from the hydraulic oil temperature switch/sensor (Z20/B123) is connected to terminal (A30) and displayed as an alarm message (see Ground drive hydraulics metal detector warning). Ground drive hydraulics metal detector warning Important: The ground drive hydraulics metal detector sensors (B127) may be installed in parallel with the temperature switch (Z20) (option). Consequently, the hydraulic oil temperature warning may also be released by the ground drive hydraulics metal detector sensors (B127).

Parking brake / brake lining monitor warning The earth signal of the parking brake switch (Z12) or brake lining monitor (Z9a/b) is sent to the terminal (A30) and displayed as an alarm message. In the diagram, the state of the switch (Z12) is shown with the parking brake applied. Straw jam warning The earth signal of switch (Z61) is sent to the terminal (A30) and displayed as an alarm message. Half-tracks steering position display For machines with half-tracks, the connector X13 is connected with the microswitches (Z38/Z39) on the steering axle.

Half-tracks tension If the oil pressure in one of the tensioning systems falls below 160 bar, the earth signal of the corresponding oil pressure switch (Z36/Z37) is sent to the indicator light (H20) and at the same time to the pulse generator via the diode PCB (DI). Hydraulic filter warning The "Hydraulic filter plugged" alarm is released when switch (Z78) is closed for more than 5 seconds (engine temperature > 60°C). 03/05 Lex-e-26a 26a-3