CLAAS LEXION 500 series (520, 570) — 38b - Automatic air conditioner

Key to diagram:

Coordinates AC Automatic air conditioner instrument lighting......................2-g-18 A6 Automatic air conditioner module .......................................2-g-18 A7 Cab fan speed controller module........................................2-g-18 B86 AC cab temperature sensor................................................2-h-17 B87 AC air discharge temperature sensor.................................2-g-18 B88 AC outside temperature sensor..........................................2-h-19 DS Diagnosis plug (63-pin) VIA.................................................3-i-20 K24 Compressor-type air conditioner relay.................................4-i-20 K51 Ignition lock relay.................................................................4-i-20 K52 Power supply relay ..............................................................4-i-20 K58 Alternator time relay.............................................................4-i-20 M7 Cab fan motor.....................................................................2-g-18 Y32 Compressor-type air conditioner electro-magnetic clutch solenoid coil........................................................................2-p-17 Y109 Heater solenoid coil ............................................................2-h-19 Z22 Compressor-type air conditioner high pressure actual value switch..............................................................2-n-17 Z23 Compressor-type air conditioner low pressure actual value switch..............................................................2-n-17 Z74 Anti-icing device actual value switch ..................................2-g-18 B86 Cab temperature sensor blue; fault by flashing code in display yellow; fault by flashing code in display red; fault by flashing code in display (Pin 85 - Pin 86) (Pin 30 - Pin 87a) (Pin 30 - Pin 87) Y109 Solenoid coil 0.8 A 15 Ω Messrs.

Konvekta Measured value table:

Item Component Measured value Remark Y32 Solenoid coil 3.0 A 4.0 Ω 20° - 97070 Ω -10° - 55330 Ω 0° - 32650 Ω 10° - 19900 Ω 20° - 12490 Ω 30° - 8057 Ω 40° - 5327 Ω 50° - 3603 Ω 60° - 2488 Ω K68 K75 Remote control relay 85±7 Ω 20A 40A B87 Air discharge temperature sensor B88 Outside temperature sensor Electric System LEXION 500 TIC 38b-2 Lex-e-38b 38b Automatic air conditioner Item Component Measured value Remark B86 Cab temperature sensor 20° - 97070 Ω -10° - 55330 Ω 0° - 32650 Ω 10° - 19900 Ω 20° - 12490 Ω 30° - 8057 Ω 40° - 5327 Ω 50° - 3603 Ω 60° - 2488 Ω blue; fault by flashing code in display B87 Air discharge temperature sensor yellow; fault by flashing code in display B88 Outside temperature sensor red; fault by flashing code in display K68 K75 Remote control relay 85±7 Ω 20A 40A (Pin 85 - Pin 86) (Pin 30 - Pin 87a) (Pin 30 - Pin 87) Y32 Solenoid coil 3.0 A 4.0 Ω Y109 Solenoid coil 0.8 A 15 Ω Messrs.

Konvekta