TIC LEXION 500 Electric System Description of function: 1/7 Automatic air conditioner Together with the cab fan speed controller module (A7), the automatic air conditioner module (A6) provides the complete temperature control inside the cab. This involves both actuating the cooling compressor electro-magnetic clutch (Y32) via relay K24 and switching the heater circuit on and off if required via solenoid coil (Y109) until the set values agree with the actual values of the corresponding sensors. The two closed gas-pressure switches (Z22/Z23) must supply relay K24 with earth in order to allow the function of the electro-magnetic clutch (Y32).
The temperature switch (Z74) prevents icing on the evaporator. If the earth signal fails due to one of the two gas-pressure switches (Z22/Z23), the electro-magnetic clutch (Y32) disengages and this fault is displayed in terminal (A30). econ operation In this operating mode, the cooling compressor is not activated. The entire air conditioner control is realised by the heater and the fan. REHEAT function In this operating mode, the cooling compressor is permanently activated. The ambient sensors (e.g. outside temperature sensor) is not considered here. Activation is for a defined period of time (see also Operator's Manual). Test menu: Key to diagram:
1 Key for activating the test menu 2 LED (without function in the test menu) 3 Key for activating the test menu 4 LED (without function in the test menu) 5 Key (without function in the test menu) 6 Key (without function in the test menu) 7 LED bar display indicates the evaporator fan speed 8 Display field (3 digits) Indicates the temperature in the test menu. 9 Display (1 digit). Indicates the measuring points in the test menu. 10 LED (without function in the test menu) 11 Key for leaving the test menu. A RESET is carried out after confirmation. 12 LED (without function in the test menu) 13 Key for activating the test menu LED (without function in the test menu) 03/05 Lex-e-38b 38b-3