TIC LEXION 500 Electric System Description of function: 5/7 7th menu item Fan speed (50%) Cab fan (M7) Press key (3) once. The fan speed (50%) of the cab fan (M7) is activated. Example: Test step 7 is displayed The speed is displayed as a bar display. If the cab fan does not start, please check the following: 1. Connector on the cab fan (below the roof cover). 2. Check the cab fan motor mechanically. Abraded particles of carbon brushes 3. Connector on the automatic air conditioner module (A6). 4. Fuse (F33, 1.5A) 5. Check cable to the cab fan motor (M7) for short-circuit or break. 8th menu item Fan speed (80%) Cab fan (M7) Press key (3) once.
The fan speed (80%) of the cab fan (M7) is activated. Example: Test step 8 is displayed The speed is displayed as a bar display. If the cab fan does not start, please check the following: 1. Connector on the cab fan (below the roof cover). 2. Check the cab fan motor mechanically. Abraded particles of carbon brushes 3. Connector on the automatic air conditioner module (A6). 4. Fuse (F33, 1.5A) 5. Check cable to the cab fan motor (M7) for short-circuit or break. 03/05 Lex-e-38b 38b-7