CLAAS LEXION 500 series (520, 570) — 38b - Automatic air conditioner

Electric System LEXION 500 TIC Description of function: 6/7 9th menu item Fan speed (100%) Cab fan (M7) Press key (3) once. The fan speed (100%) of the cab fan (M7) is activated. Example: Test step 9 is displayed The speed is displayed as a bar display. If the cab fan does not start, please check the following: 1. Connector on the cab fan (below the roof cover). 2. Cab fan speed controller module (A7) below the roof cover. Slacken off the cover screws and remove the cover. 3. Voltage on the cab fan motor. Target value: 11.5 – 14.5 V. The cab fan speed controller module (A7) must be connected. 4. Check the cab fan motor mechanically. Abraded particles of carbon brushes 5.

Connector on the cab fan speed controller (A7) 6. Fuse (F33, 1.5A) 7. Check cable to the cab fan motor (M7) for short-circuit or break. 10th menu item Automatic air conditioner module (A6) outputs Press key (3) once. All outputs of the automatic air conditioner module (A6) are activated. Example: Test step 10 is displayed The speed is displayed as a bar display. 1. The heater solenoid coil (Y109) is switched on. 2. The compressor-type air conditioner electro-magnetic clutch solenoid coil (Y32) is activated. 3. The cab fan motor (M7) is switched on and works at max. speed. 38b-8 Lex-e-38b 03/05