Electric System LEXION Montana 570-520 TIC Description of function: 2/5 Go to page 1/6 inputs using the yellow keys and the Enter key. The parking brake symbol allows checking the function of parking brake switch S93 (symbol) – closed / open. Diag. Inputs 1/6 Handbrake Reserve 1 Reserve 2 Go to page 2/6 inputs using the yellow keys and the Enter key. The sensor value B91 is displayed. Diag. Inputs 2/6 Cylinder left Sensor: 3.30 V Cal.min.: 0.12 V Cal.max.: 4.99 V Position: 65.3% Go to page 3/6 inputs using the yellow keys and the Enter key. The sensor value B92 is displayed. Diag. Inputs 3/6 Cylinder right Sensor: 2.01 V Cal.min.: 0.00 V Cal.max.: 4.86 V Position:
41.3% Go to page 4/6 inputs using the yellow keys and the Enter key. The sensor value B93 is displayed. Diag. Inputs 4/6 Cutting angle Sensor: 3.47 V Cal.min.: 2.64 V Cal.max.: 3.80 V Position: 71.8% 41s-4 Lex-e-41s 03/05