CLAAS LEXION 500 series (520, 570) — 44a - Electro-hydraulic gearshift - 3-speed manual gearbox

TIC LEXION 500 Electric System Description of function: Electro-hydraulic gearshift As a pre-condition for carrying out an electro-hydraulic drive range changeover, the signals of the actual value switch Z57 (ground speed control lever in neutral position), Z79 and Z80 (actuation of both service brakes) must be identified by the electro-hydraulic gearshift (EHS) module A37. Module A37 (EHS) controls the solenoid coils Y107, Y108 and Y123 of the gear preselection correspondingly via switches S70 and S71. The master valve (Y77) is also actuated via the diode PCB (DO) in parallel with the solenoid coils by module A37 (EHS) because these functions require that pressure is built up in the system.

The realization of the drive range changeover is controlled by module A37 (EHS) via the actual value switches Z82, Z83, Z95, Z97 and Z96. Module A37 (EHS) performs several gearshift processes under program control for changing over the drive range if necessary if the changeover process is hindered by external influences on the gearshift. If the selected gear cannot be engaged within 1 second, another attempt is made for engaging other gears. An error message in terminal (A30) appears when the gear cannot be engaged within 4 seconds. At the same time, the gearbox neutral signal light H63 flashes. The gear engaged is indicated by the signal lights H60, H61, H62 and H63.

Supply voltage of gearshift actual value switches The supply voltage of the gearshift actual value switches from pin 8 of module A37 (EHS) is 12 volt and is limited to a current consumption of 200 mA max. Important! Suitable measuring devices must be used for error diagnosis. Diagnosis Errors occurred during the gearshift process are displayed as messages on terminal A30. Gearshift logic EHS 3-speed:

03/05 Lex-e-44a 44a-3 1st gear engaged 2nd gear engaged 3rd gear engaged 2nd and 3rd gear neutral position 1st gear neutral position Designation Z82 Z83 Z95 Z97 Z96 Switch type NO contact NO contact Changeover contact NO contact NO contact Module A37 Pin 11 Pin 12 Pin 13 Pin 10 Pin 17 1st gear 12 V (200 mA) 0 V 0 V 12 V (200 mA) 0 V 2nd gear 0 V 12 V (200 mA) 0 V 0 V 12 V (200 mA) 3rd gear 0 V 0 V 12 V (200 mA) 0 V 12 V (200 mA) Neutral 0 V 0 V 0 V 12 V (200 mA) 12 V (200 mA)