CLAAS LEXION 500 series (520, 570) — 44a - Electro-hydraulic gearshift - 3-speed manual gearbox

Electric System LEXION 500 TIC Possible errors: Brake pressure switch of gearshift defective When the signal from switches Z79 and Z80 has been identified for more than 30 minutes, the message "Braking pressure switch for gear-shift mechanism defective" is displayed on terminal A30. Shifting gears is prevented until the signals from switches Z79 and Z80 are again identified as being a correct function. The error is stored in the error memory.

Ground speed control lever neutral position defective If signals from the ground speed sensor (B16) are still present although the "Ground speed control lever neutral" signal has been detected, the message "Ground speed control lever neutral position switch defective" is displayed on terminal A30. Shifting gears is prevented until a correct function is again detected. The error is stored in the error memory (see also diagram 25). Gearshift operating error If the signals from the brake circuit pressure switches Z79 and Z80 or from the ground speed control lever neutral switch Z57 are interrupted during the shifting process, the changeover is not carried out any more.

The message " Ground speed lever in neutral position! / Apply foot brake – otherwise unable to change gear! " is displayed on terminal A30. 44a-4 Lex-e-44a 03/05