Automatic Lubrication System - Section 42 OM4210 Page 42-10 SYSTEM CHECKOUT To check system operation (not including timer), proceed as follows: The third dip switch is for selecting the units for the “off time” to be used in conjunction with off time switch (1). Hours or minutes may be selected. 1. Start the engine. The fourth dip switch is used to select “memory off” or “memory on”. When the switch is set to “memory off”, a lube cycle will occur each time power is turned on. The lube cycle will start at the beginning of the on time setting. 2. Actuate the test switch at the reservoir/pump assembly. 3. The motor and pump should operate until the system attains 17,237 kPa (2500 psi). 4.
Once the required pressure is achieved, the pump motor should turn off and the system should vent. When the switch is set to “memory on”, the controller will function as follows: 1. When power is turned off during ‘off time’ (between cycles), the lube cycle will resume at the point of interruption after power is restored. In other words, the controller will remember its position in the cycle. 5. Check for pump, hose or injector damage or leakage with the system under pressure. 6. After checking system, stop the engine. Observing normal precautions regarding high voltage present in the propulsion system before attempting to repair lube system. 2.
When power is turned off during ‘on time’ (during a cycle), the controller will reset to the beginning of the lube cycle after power is restored. Lubrication Controller Check Pressing the manual lube button on the enclosure cover will initiate a lube event (see Figure 42-7). Off time switch (1) is used to select units of time. Possible time intervals are: 0.5, 1, 2, 4, 8, 15, 24 or 30. The mode switch determines whether the off time units will be minutes or hours. Lubrication Controller Operation The time between lube events is determined by the setting of the rotary switch, which selects the numeral setting, and the dip switch, which selects the units in either minutes or hours.
Cover (3) contains three LED windows and a manual lube switch. The LEDs indicate system operation and status. When power is on, a green LED will illuminate. When the pump is on, another green LED will illuminate. A red LED will illuminate when an alarm condition occurs. Lubrication Controller Components Mode switch (2, Figure 42-7) consists of four dip switches. The first dip switch controls the maximum amount of “on time”, either 30 seconds or 120 seconds. Lubrication Controller Adjustment The second dip switch controls the mode, either timer mode or controller mode.
When the switch is set to the timer mode, the amount of time that the pump is on will be determined by the setting of the dip switch (30 seconds or 120 seconds). When the switch is set to the controller mode, a pressure switch must be installed in the lube supply line. The pressure switch will detect supply line pressure, and will reset the timer at a set pressure. If the pump fails to reach the set pressure within the dip switch setting (30 seconds or 120 seconds), the controller will initiate an alarm. The lubrication controller is factory adjusted to the following switch settings:
Dip Switch 1 - 120 SEC Dip Switch 2 - TIMER Dip Switch 3 - MINUTES Dip Switch 4 - MEMORY OFF Rotary Switch - 15 minutes