Komatsu — Hydraulic Oil Temperature Gauge

Operator Cab And Controls - Section 32 OM3242 Page 32-18 Manual Backup Switch Manual backup switch Figure 32-7) allows the backup lights to be turned on for added visi- bility and safety when the selector switch (see Operator Controls) is not in REVERSE position. When the switch is in the ON position, the manual back up light indicator (B4, overhead panel, Figure 32-8) will be illuminated. Fog Lights (Optional) Fog lights (19, Figure 32-7) are optional equipment that are useful in foggy conditions and heavy rain. Pressing the top of the rocker switch turns the fog lights on. Pressing the bottom of the switch turns the lights off. engine idle speed will increase to help cool the oil.

Red indicates high oil temperature in the hydraulic tank. Continued operation could damage compo- nents in the hydraulic system. There is also a red temperature warning light in the overhead panel (A1, Figure 32-8) that will illuminate when the temperature exceeds a certain level (when the needle enters the red zone). If this condition occurs, the operator must safely stop the truck, move selector switch to PARK, and operate engine at 1200 - 1500 rpm to reduce system temperature. Payload Meter Switch Payload meter switch (20, Figure 32-7) is a two-way, momen- tary rocker switch. The top position is the SELECT position. The SELECT position is used to step through the different displays.

The lower position is the SET position. The SET position is used to set the operator ID, or clear the load and total ton counters. Refer to Section 60, Payload Meter III, for a more complete description of the pay- load meter system and its functions. If temperature gauge does not move into the green range after a few minutes, and the red overhead indicator light does not go out, stop the engine and notify maintenance personnel imme- diately. Panel Light Dimmer (18, Panel light dimmer (21, Figure 32-7) ckup is a rheostat which allows the opera- d visi- tor to vary the brightness of the lector instruments and panel lights.

ls) is When n, the • Rotating the knob to the full clockwise position (B4, turns the panel lights on to the brightest ill be condition. • Rotating the knob counterclockwise continually dims the lights until OFF position is reached at full counterclockwise rotation. Hydraulic Oil Temperature Gauge ) are Hydraulic oil temperature gauge (22, eful in Figure 32-7) indicates oil tempera- rain. ture in the hydraulic tank. There are switch two colored bands: green and red. ng the lights Green indicates normal operation. As the needle approaches the red zone, minimum