Multiplexed Electrical System Service Manual 7 PM819023/KM815057 (08/14/2012) 7 - 7 CECU Parameter Part Number Parameter Description Min. Value Max. Value Explanation Q30-1024-054 Dash Backlight Day Value 0 255 Parameter is used to set the intensity of the backlighting for the entire dash when the lights are not on. Value 0 means minimum illumination. Value 255 means maximum illumination. Q30-1024-055 Dash Dim With Dome Light 0 1 Parameter is used to determine if the dash backlighting should dim if the dome light is on. Value 0/Disabled means the functionality is disabled. Value 1/Enabled means the functionality is enabled.
Q30-1024-056 TFT Backlight Day Value 0 255 Parameter is used to set the intensity of the backlighting for the information display when the lights are not on. Value 0 means minimum illumination. Value 255 means maximum illumination. Q30-1024-058 Transfer Case Temperature Sensor Type 0 1 Parameter is used to determine which type of transfer case temperature sensor is installed for the transfer case temperature gauge. This determines the input range. Value 0 means Transfer Case Temperature Sensor Type = Delphi. Value 1 means Transfer Case Temperature Sensor Type = Siemens (or Continental).
Q30-1024-059 Park Brake Symbol In Indication Bar 0 1 Parameter is used to determine if the park brake symbol is available on the indicator bar located on the RH side of the information display. Value 0/Disabled means park brake symbol will not be displayed. Value 1/Enabled means park brake symbol will be displayed. Q30-1024-060 PTO Control Present 0 1 Parameter is used to determine the presence of PTO controls. (For CUMMINS engine, default value is 1 - Cruise Control PTO idle bump). Value 0/Disabled means PTO Control functionality is disabled. Value 1/Enabled means PTO Control functionality is enabled.
Q30-1024-062 After Treatment Regeneration Switch 0 1 Parameter is used to determine if the Diesel Particulate Filter (DPF) aftertreatment regeneration force or inhibit switches are installed. Value 0/Disabled means After Treatment Regeneration Switch is not installed. Value 1/Enabled means After Treatment Regeneration Switch is installed. Q30-1024-063 Remote PTO Present 0 1 Parameter is used to determine if the remote PTO switches are installed (PACCAR engines only). Value 0/Disabled means Remote PTO switches are not installed. Value 1/Enabled means Remote PTO switches are wired to CECU and functionality is enabled.
Q30-1024-064 RPM Sweet Spot High Limit 0 3000 Parameter is used to set the high limit for RPM sweet spot bargraph displayed on the information display. Q30-1024-065 RPM Sweet Spot Low Limit 0 3000 Parameter is used to set the low limit for RPM sweet spot bargraph displayed on the information display. Q30-1024-066 Transmission Make 0 4 Parameter is used to determine the type/make of transmission. Value 0 - Manual transmission. Value 1 - Autoshift transmission. Value 2 - Ultrashift transmission. Value 3 - Freedomline transmission. Value 4 - Allison transmission.