PACCAR Corporation — Parameter Part Numbers

7 Multiplexed Electrical System Service Manual 7 - 8 PM819023/KM815057 (08/14/2012) CECU Parameter Part Number Parameter Description Min. Value Max. Value Explanation Q30-1024-067 Brake Applied Pressure Sensor Installed 0 1 Parameter is used to determine if the brake application pressure sensor is installed. This parameter will effect the functionality of the brake applied gauge and cruise control. Value 0/Disabled means brake application pressure sensor is not installed. Brake applied gauge will not function and CECU will not send brake info on databus. Value 1/Enabled means brake application pressure sensor is installed.

Brake applied gauge will be enabled (If "Brake Applied Pressure Gauge Installed" parameter is also enabled) and CECU will send brake info on databus. Q30-1024-068 Dome Light Controlled By Low Voltage Disconnect 0 1 Parameter is used to determine if the dome lamps are controlled by the LVD. Value 0/Disabled means the dome lamps are not controlled by the LVD. Value 1/Enabled means the dome lamps are controlled by the LVD. Q30-1024-069 LVD Sytem Dropout Voltage 0 600 Parameter is used to determine the voltage cutout to turn off the dome lamps. Default setting is 121: or 12.1 volts.

Q30-1024-070 Alarm Bell Symbol 0 2 Parameter is used to determine the status of the alarm bell symbol in the information display. Value 0 means the alarm bell symbol is off. Value 1 means the alarm bell symbol is on solid. Value 2 means the alarm bell symbol is animated. Q30-1024-071 Ignition Timer Maximum Time 5 90 Parameter is used to determine the maximum time the idle timer can be set to. The value can be set in one minute increments. Value 5 means five minutes. Value 90 means ninety minutes. Q30-1024-072 Voltage Trim Multiplier 0 999999 Parameter is used to trim or calibrate the voltmeter. This value is the "multiplier" portion of the trim and has a range between 0 and 999999.

See Voltmeter Trim Procedure on page 7-21 following this chart, for steps to determine the correct value. Q30-1024-073 Voltage Trim Offset 0 10000 Parameter is used to trim or calibrate the voltmeter. This value is the "offset" portion of the trim and has a range between 0 and 10000. See Voltmeter Trim Procedure on page 7-21 following this chart, for steps to determine the correct value. Q30-1024-074 Low Voltage Disconnect Installed 0 1 Parameter is used to determine if a low voltage disconnect system is installed. Value 0/Disabled means a LVD system is not installed. Value 1/Enabled means a LVD system is installed.

Q30-1024-075 Engine Fan With Park Brake Installed 0 1 Parameter is used to determine if an engine fan override is available to the operator. This override will allow the operator to turn the engine fan on when the park brakes are set and the engine ECU permits the fan to turn on. Value 0/ Disable means that this function is not enabled and the operator cannot control when the engine fan turns on. Value 1/Enabled means that the operator may turn the engine fan on when the park brakes are on and the engine ECU permits the fan to be on. Q30-1024-076 Primary Air Pressure on V-CAN 0 1 Parameter is used to determine if the primary air pressure is broadcast on the V-CAN.

Value 0/Disabled means the primary air pressure is not broadcast on the V-CAN. Value 1/Enabled means the primary air pressure is broadcast on the V-CAN.