PACCAR Corporation — Parameter Part Numbers

Multiplexed Electrical System Service Manual 7 PM819023/KM815057 (08/14/2012) 7 - 9 CECU Parameter Part Number Parameter Description Min. Value Max. Value Explanation Q30-1024-077 Secondary Air Pressure on V-CAN 0 1 Parameter is used to determine if the secondary air pressure is broadcast on the V-CAN. Value 0/Disabled means the secondary air pressure is not broadcast on the V-CAN. Value 1/Enabled means the secondary air pressure is broadcast on the V-CAN. Q30-1024-078 Voltage on V-CAN 0 1 Parameter is used to determine if voltage is broadcast on the V-CAN. Value 0/Disabled means voltage is not broadcast on the V-CAN. Value 1/Enable means voltage is broadcast on the V-CAN.

Q30-1024-079 Primary Fuel Level on V-CAN 0 1 Parameter is used to determine if the primary fuel level is broadcast on the V-CAN. Value 0/Disabled means the primary fuel level is not broadcast on the V-CAN. Value 1/Enable means the primary fuel level is broadcast on the V-CAN. Q30-1024-080 Secondary Fuel Level on V-CAN 0 1 Parameter is used to determine if the secondary fuel level is broadcast on the V-CAN. Value 0/Disabled; not broadcast on the V-CAN. Value 1/Enable; broadcast on the V-CAN. Q30-1024-082 Smart Wheel Installed 0 1 Parameter is used to determine if a smart wheel is installed. This parameter enables the cluster retarder lamp.

This lamp is only enabled when the truck is equipped with a multiplex steering wheel. Value 0/Disabled means a smart wheel is not installed. Value 1/Enable means a smart wheel is installed. Q30-1024-083 Governed Speed Limit Available 0 1 Parameter controls if the Governed speed limit transmitted by the Engine on V-CAN is displayed on the "Engine Info" MFD screen. Value 0/Disabled means the Governed Speed Limit is not Displayed Value 1/Enable means the Governed Speed Limit is displayed, if the Engine is transmitting it. Q30-1024-084 Remote Accelerator Sensor Installed 0 1 Parameter controls fault logging for Remote Accelerator input (C27 of CECU).

Also controls transmission of Remote Accelerator information on V-CAN. Value 0/Disabled means that no DTCs will be logged if that input is in a failure state (open, short) and "Not Available" is transmitted on V-CAN Value 1/Enable means that DTCs will be logged if that input is in a failure state (open, short). The remote accelerator values on V-CAN are populated with valid data (or "Error" if a fault is occurring on the input). Q30-1024-085 Axle Temperature Steer Gauge Installed 0 1 Parameter controls fault logging of analog input and gauge outputs to CVSG.

(For Peterbilt Only) Value 0/Disabled means that no DTCs will be logged if that input is in a failure state (open, short) and the gauge needle will not move if connected to the CVSG bus. Value 1/Enable means that DTCs will be logged if that input is in failure state (open, short) and the gauge needle will move when connected to the CVSG bus.