PACCAR Corporation — Parameter Part Numbers

7 Multiplexed Electrical System Service Manual 7 - 12 PM819023/KM815057 (08/14/2012) CECU Parameter Part Number Parameter Description Min. Value Max. Value Explanation Q30-1024-103 Turn Lamps Trailer Installed 0 1 Parameter controls the outputs for the trailer outputs 0/Disabled means with the hardware installed, the lamps will work, but the diagnostics will not (except short circuits) Value 1/Enabled means outputs and diagnostics are enabled. If it is enabled with no hardware installed, you will get constant open circuit errors.

Q30-1024-104 OAT Source 0 1 Parameter controls the signal used to populate the LCD in the Tachometer, as well as all other CECU features that use temperature as part of the algorithm. Value 0/CECU means that the analog input of the CECU is used (non-OBD engines). Value 1/Engine means that the J1939 V-CAN input from the Engine will be used. Q30-1024-105 Backup Alarm Mute Enabled 0 1 Parameter controls the backup alarm mute functionality. Value 0/Disabled means the backup alarm will never be muted. Value 1/Enabled means the external backup alarm speaker will be muted when the dash switch is activated by the operator.

Q30-1024-106 Pre Trip Lighting Test Enabled 0 1 Parameter controls the availability of the Pre Trip Lighting Test. Value 0/Disabled means the menu item in the settings menu is not available and the Pre Trip sequence will never be executed. Value 1/Enabled means the menu item is available in the settings menu. When the operator enables it, the pre trip lighting sequence will be initiated. Q30-1024-107 Pre Trip Test Sequence Interval 10s 30s Parameter controls the interval of the pre trip lighting test. This is how long it stays in any one mode before transition to the next test mode. Q30-1024-108 Enable Gateway 0 1 Parameter controls the gateway functionality.

This must be enabled for the following Gateway parameters to take effect. Value 0/Disabled means no Gateway of messages will occur. Value 1/Enabled means the settings of the following gateway parameters will be observed. Q30-1024-109 Enable Router 0 1 Parameter controls the router functionality. This must be enabled for the following Router parameters to take effect. Value 0/Disabled means no Routing of messages will occur. Value 1/Enabled means the settings of the following router parameters will be observed. Q30-1024-110 Gateway Engine CCVS Message 0 64 Parameter controls the settings for this individual message. Add the numbers together for multiple destinations.

Value 0; OFF Value 1; B-CAN Value 2; C-CAN Value 4; D-CAN Value 8; F-CAN Value 16; I-CAN Value 32; V-CAN