12 Multiplexed Electrical System Service Manual 12 - 4 PM819023/KM815057 (08/14/2012) DTC Input Received By Item / System Description Detailed Description 11804 CECU Secondary Air Pressure Short in secondary air pressure circuit This DTC will be recorded when the control unit sees a short to +5V at the secondary air pressure sensor input. Some possible causes for this are a pinched wire, water in a connector, or sensor failure. 15802 CECU Ignition Power Ignition Power is in an indeterminate state This DTC will be recorded when the control unit sees between 33% and 66% of battery voltage on the ignition pin. A possible cause for this is faulty ignition sense wiring.
The ignition sense wire comes from the power distribution box to the control unit behind the cup holder. This sense wire is also used for other control units such as the door modules and cluster. The wiring to those control units may be the issue. 15803 CECU Ignition Power 12V is on control unit ignition pin but not on cluster ignition pin This DTC will be recorded when the control unit sees 12V on control unit ignition pin but not on cluster ignition pin. Some possible causes for this are a broken wire, corroded or disconnected connector. Ignition power is supplied to the cluster from the power distribution box near the drivers left foot through the IP harness to the cluster.
15804 CECU Ignition Power 12V is on cluster ignition pin but not on control unit ignition pin This DTC will be recorded when the control unit sees 12V on cluster ignition pin but not on control unit ignition pin. Some possible causes for this are a broken wire, corroded or disconnected connector. Ignition power is supplied to the control unit from the power distribution box near the drivers left foot through the IP harness to the control unit behind the cup holder. 16800 CECU Control Unit Battery Voltage Over voltage The control unit continually monitors the voltage it is supplied. If the voltage is above 16.5 volts the system will record this fault.
Some possible causes for this fault are faulty alternator, or jump starting with to high of voltage. Power is supplied from the power distribution box near the drivers left foot through the IP harness to the control unit behind the cup holder. 16801 CECU Control Unit Battery Voltage Under voltage for more than 10 minutes The control unit continually monitors the voltage it is supplied. If the voltage is below 8.4 volts for 10 minutes the system will record this fault. Some possible causes for this fault are low batteries, too much system load, faulty alternator, or corroded connectors.
Power is supplied for the power distribution box near the drivers left foot through the IP harness to the control unit behind the cup holder. 17102 CECU Outside Air Temp Outside air temp message from engine error This DTC will be recorded when the CAN signal for the outside air temperature sensor from the engine is in the invalid range. Some possible causes for this are broken wire or sensor failure. Modifying the sensor or its location can impact vehicle performance, emissions, and/or reliability. 17103 CECU Outside Air Temp Open in outside air temp circuit This DTC will be recorded when the control unit sees an open at the outside air temperature sensor input.
Some possible causes for this are a broken wire, corroded or disconnected connector, or sensor failure.