12 Multiplexed Electrical System Service Manual 12 - 14 PM819023/KM815057 (08/14/2012) DTC Input Received By Item / System Description Detailed Description 286304 Wiper Short in wiper relay output This DTC will be recorded when the control unit sees a short to ground at the wiper output relay. Some possible causes for this are a pinched wire or water in a connector. 286307 CECU Wiper Out of range on low speed wiper switch input This DTC will be recorded when the control unit sees an out of range voltage value on the low speed wiper switch. Some possible causes are broken wire, corroded or disconnected connector or faulty turn stalk switch.
286602 Washer Invalid range on washer pump switch input This DTC will be recorded when the control unit sees a invalid range of washer pump switch input. Some possible causes are broken wire, corroded or disconnected connector or faulty turn stalk switch. 286603 Washer Open in washer pump relay output This DTC will be recorded when the control unit sees an open at the washer pump output relay. Some possible causes for this are a broken wire, corroded or disconnected connector. 286604 Washer Short in washer pump relay output This DTC will be recorded when the control unit sees a short to ground at the washer pump output relay.
Some possible causes for this are a pinched wire or water in a connector. 286612 CECU Washer Switch Short in washer pump switch input or input active for more than 15 seconds This DTC will be recorded when the control unit sees a washer pump switch input active for more than 15 seconds. The control unit determines that a washer pump active for longer than 15 seconds may be a short circuit. Some possible causes for this are a pinched wire, corrosion or water in the connector or faulty turn stalk switch.
287204 CECU Flash to Pass Switch Short in flash to pass switch input or input active for more than 10 seconds This DTC will be recorded when the control unit sees the flash to pass switch active for more than 10 seconds. The control unit determines that a Flash to Pass switch input active for longer than 10 seconds may be a short circuit. Some possible causes for this are a pinched wire, corrosion or water in the connector or faulty turn stalk switch. 287304 CECU Marker Lamp Flash Switch Short in marker lamp flash switch input or input active for more than 10 seconds This DTC will be recorded when the control unit sees the marker lamp flash switch input active for more than 10 seconds.
The control unit determines that a marker lamp flash switch input active for longer than 10 seconds may be a short circuit. Some possible causes for this are a pinched wire, corrosion or water in the connector or faulty marker lamp flash switch.