2-38 MMP board CN114 to CN119, and CN123 basic conditions (battery plug connected, key switch ON, direction lever at N, and motor cable disconnected) Connector No.⇔Connector No.
Conditions Standard Remarks CN113-11 CN113-24 (156, TMDBD1+) (N2, TMDBD-SD) 13 ~ 15 V CN113-12 CN113-25 (158, TMDCU1+) (P7, TMDCU-SD) 13 ~ 15 V CN113-13 CN113-26 (160, TMDCD1+) (N2, TMDCD-SD) 13 ~ 15 V CN113-14 (P5, TMDAU-SD) Immeasurable ⎯ CN113-15 (N2, TMDAD-SD) Immeasurable ⎯ CN113-16 (P6, TMDBU-SD) Immeasurable ⎯ CN113-17 CN113-14 (150, TMDAU2+) (P3, TMDAU-SD) 13 ~ 15 V CN113-18 CN113-15 (152, TMDAD2+) (N2, TMDAD-SD) 13 ~ 15 V CN113-19 CN113-16 (154, TMDBU2+) (P5, TMDBU-SD) 13 ~ 15 V CN113-20 CN113-24 (156, TMDBD2+) (N2, TMDBD-SD) 13 ~ 15 V CN113-21 CN113-25 (158, TMDCU2+) (P7, TMDCU-SD) 13 ~ 15 V CN113-22 CN113-26 (160, TMDCD2+) (N2, TMDCD-SD) 13 ~ 15 V CN113-23 Unused ⎯ CN113-24 (N2, TMDBD-SD) Immeasurable ⎯ CN113-25 (P9, TMDCU-SD) Immeasurable ⎯ CN113-26 (N2, TMDCD-SD) Immeasurable ⎯ Connector No.⇔Connector No.
Conditions Standard Remarks CNOOO-1 CNOOO-3 (TM ***2+) (TM ***-SD) 14 ~ 15 V CNOOO-2 CNOOO-3 (TM ***1+) (TM ***-SD) 14 ~ 15 V CNOOO-3 ⎯ (TM ***-SD) ⎯ CNOOO-4 CNOOO-3 (TM ***-G) (TM ***-SD) 13 ~ 15 V