2-39 Traverling/material handling controller (15 ~ 32 model) CN137 basic conditions (battery plug connected, key switch ON, direction lever at N, and motor cable disconnected) CN139 basic conditions (battery plug connected, key switch ON, direction lever at N, and motor cable disconnected) Connector No.⇔Connector No. Conditions Standard Remarks CN137-1 CN137-3 (2, MD-) (1, MD+) Battery plug disconnected Resistance measurement Approx. 20 Ω CN137-2 (N2, N2) Immeasurable ⎯ CN137-3 CN137-1 (1, MD+) (2, MD-) Measurement with (-) probe in con- tact with CN137-1 Approx. 11 V CN137-4 CN137-5 (6, MP-) (5, MP+) Battery plug disconnected Resistance measurement Approx.
20 Ω Chopper-less CN137-5 CN137-4 (5, MP+) (6, MP-) Measurement with (-) probe in con- tact with CN137-4 Approx. 11 V Chopper-less CN137-6 (44, F6) ⎯ Connector No.⇔Connector No. Conditions Standard Remarks CN139-1 CN139-2 (18, FAN3+) (N2, FAN3-) Approx. 24 V CN139-2 (N2, FAN3-) Immeasurable ⎯