Komatsu — BEFORE STARTING ENGINE

. OPERATION MACHINE OPERATIONS AND CONTROLS Check Oil Level in Hydraulic Tank, Add Oil WARNING and may cause burns. Wait for the C (50 to 86 ° F)) C (122 to 176 ° F)) 3 - 118 The parts and oil are at high temperature to go down before When removing the oil filler cap , turn it slowly to release the internal pressure, th . Set the work equipment in t he posture shown in the diagram on the right, then check the oi l level and add oil if necessary. not in the condition shown in the the engine, run the engine at low . If the work equipment is diagram on the right, start speed, retract the arm an lower the boom, set the buc and stop the engine. .

Within 15 seconds after d bucket cylinder rods fully, then ket teeth in contact with the ground, stopping the engine, move each control lever (for work equi in all directions to release t pment and travel) to the full stroke he internal pressure. . Open the door or the left si de of the machine and check sight gauge (G). The oil level is n ormal if between the H and L marks. . If the level is below the L m ark, add oil through oil filler (F) at the top of the hydraulic tank. REMARK The oil level will vary dependin Accordingly, use the following Before starting operation: B (Oil temperature 10 to 30°C Normal operation: Around (Oil temperature 50 to 80°C NOTICE Do not add oil above the H line.

T his will damage the hydraulic circuit or cause the oil to spurt out. the H level, swing the upper structure If oil has been refilled, exceeding until drain plug (P) beneath the hyd raulic tank comes between the right and lef t track shoes and stop the e ngine. Wait for the oil to cool down sufficiently, then remove cover (1) and drain the excess oil through drain