Initialization procedures for VHMS controller 1 1. Check of machine information, engine information and controller information a This step is a work performed on the whole machine. Check and record the machine information, engine information, VHMS controller informa- tion and ORBCOMM terminal information. a Initialization tools for VHMS controller * VHMS setup tool Ver3.06.00.03 or newer VHMS analysis tool Ver3.05.00.00 or newer a Before starting full operation after completion of local assembly or before resuming operation after storage for a long period, initialize the VHMS controller according to the following procedure.
a Machine data collected with the VHMS control- ler are stored and managed in WebCARE database. To process the data smoothly on the WebCARE, it is necessary to set the VHMS controller consistently. If it is not set correctly, data will not be taken into the WebCARE and data in the VHMS controller may not be uti- lized. Accordingly, be sure to carry out the ini- tialization. a For the method of installing the VHMS Initial- ization Program to the personal computer, refer to the Operation and Maintenance Man- ual contained in the package of diskette Z1 .
a Since the service menu of the monitor panel will be used in the following procedure, read "Special functions of monitor panel" and under- stand the operating procedure in advance. a The initialization procedures cover both "ORB- COMM Specification" and "ORBCOMMLESS Specification". In case of "ORBCOMMLESS” Specification", omit the procedures necessary for "ORBCOMM Specification" only. a During the initialization work, confirm each work according to the "VHMS Initialization Work Checklist". a VHMS controller (1) is in the control box on the left side of the floor and ORB- COMM terminal (2) is in the control box on the right side of the floor. 186 Symbol Part No.
Part name Z 1 799-608-3211 Diskette 2 799-608-3220 Wiring harness 3 Commercially available Notebook type personal com- puter (OS: Windows98/2000/ NT/Me/XP/VISTA* Terminal "RS232C" is with it) No. Information to be checked 1 Machine model 2 Machine serial No. 3 Current service meter reading 4 Engine serial No. 5 Transmission serial No. 6 VHMS controller serial No. 7 ORBCOMM terminal serial No. [For ORBCOMM specification only]