Kaiyi D375A-6 — APPENDIX 2. Precautions for initialization procedures for VHMS controller

2. Connection of personal computer 1) Make sure that the starting switch is in the OFF position. k Be sure to connect and disconnect the personal computer while start- ing switch is in the OFF position. 2) Connect personal computer Z3 and down- load connectors (VDW) and (DL1) by wir- ing harness Z2 . a The download connectors are installed to the following places. q (VDW): Inside of cab (Left rear lower part) q (DL1): Left rear side of machine (Side of backup lamp) a Connect the personal computer to the RS232C terminal. 3. Check of operation and satellite capturing condition of VHMS controller a This step is a work performed in the oper- ator's cab.

a Check of satellite capturing condition is necessary o only [ORBCOMM specifica- tion]. 1) Set the starting switch in the ON position. 2) Switch the monitor panel to Service Menu and select "Monitoring". 3) Input ID = 99003. Monitoring MAN 99003 Orbcomm Communication Status Orbcomm Con. Power ON Satellite Condition On Date Transmission OFF a Execute initialization of VHMS from the connector in the cab. a Use the ground download connector for only downloading. Monitoring Hold 4) Judge the operation of the ORBCOMM controller by the state of the dot at the right bottom of the LED digit of the VHMS controller. 187