Komatsu — ELECTRICAL SYSTEM

OPERATION 2 OTHER TROUBLE { } : Always contact your distributor when handling these items. In cases of abnormalities or causes which are not listed below, please contact your distributor for repairs. 2 ELECTRICAL SYSTEM D87E-2 D87P-2 2-93 PROBLEM MAIN CAUSE REMEDY Voltmeter does not register charge when engine runs at high idle or flickers while engine is running • Defective wiring. . . . . . . . . . . . . . . . . . • Defective adjustment of belt tension . . {Check, repair loose terminals, discon- nections} Adjust, see “ENGINE FAN AND AL- TERNATOR BELT” on page 3-44 Voltmeter registers extreme high charge • Defective alternator . . . . . . . . . . . . . . . • Defective wiring. . . . . . . .

. . . . . . . . . . {Replace} {Check, repair} Abnormal noise is generated from alter- nator • Defective alternator . . . . . . . . . . . . . . . {Replace} Starting motor does not turn when key switch is turned on • Defective wiring. . . . . . . . . . . . . . . . . . • Insufficient battery charge . . . . . . . . . . {Check, repair} Charge Pinion of starting motor keeps going in and out • Insufficient battery charge . . . . . . . . . . Charge Starting motor turns engine sluggishly • Insufficient battery charge . . . . . . . . . . • Defective starting motor. . . . . . . . . . . . Charge {Replace} Starting motor disengages before engine starts • Defective wiring. . . . . . . . . . . . . . . . .

. • Insufficient battery charge . . . . . . . . . . {Check, repair} Charge Automatic preheating is not actuated • Defective wiring. . . . . . . . . . . . . . . . . . • Defective glow heater. . . . . . . . . . . . . . • Defective timer. . . . . . . . . . . . . . . . . . . {Check, repair} {Replace} {Replace} Glow signal lamp does not go out • Defective wiring. . . . . . . . . . . . . . . . . . • Defective heater relay. . . . . . . . . . . . . . {Check, repair} {Replace} Glow signal lamp does not glow red • Defective wiring. . . . . . . . . . . . . . . . . . • Defective heater relay. . . . . . . . . . . . . . • Defective glow signal. . . . . . . . . . . . . .

{Check, repair} {Replace} {Replace} Warning lamps do not illuminate when engine is stopped, start switch at on po- sition, possible 8 places • Defective warning lamp . . . . . . . . . . . . • Defective lamp switch . . . . . . . . . . . . . • Defective wiring. . . . . . . . . . . . . . . . . . {Replace} {Replace} {Check, repair} Outside of electrical intake air heater is not warm when touched by hand • Defective wiring. . . . . . . . . . . . . . . . . . • Disconnection in electrical intake air heater . . . . . . . . . . . . . . . . . . . . . . . . . . • Defective operation of heater relay switch . . . . . . . . . . . . . . . . . . . . . . . . . .

{Check, repair} {Replace} {Check repair switch} Air conditioner does not work • Blown fuse . . . . . . . . . . . . . . . . . . . . . . • Insufficient battery charge . . . . . . . . . . • Defective air conditioner switch. . . . . . • Defective blower switch. . . . . . . . . . . . • Defective compressor. . . . . . . . . . . . . . {Check repair switch} Charge {Replace switch} {Replace switch} {Replace}