MAINTENANCE Diagonal Strut Joints 1 FITTING 3 Apply grease until clean lubricant is visible. Always use a clean lubrica- tor and wipe dirt from fittings before fresh grease is applied. If grease fails to go through the fitting, determine the cause and correct it. After greasing, wipe off any old grease that was purged. 3 REVERSIBLE FAN Keep clear of fan and fan belts when the engine is running. Rotating fan and belt contact will result in serious injury. The fan blades must be reversed to prevent corrosion and dirt build up that may cause binding of the shafts in the fan hub. After reversing the blades return the blades to the desired position.
3 CHANGE ENGINE CRANKCASE OIL AND FILTER The oil is at high temperature after the engine has been operated, so never change the oil immediately after finishing operations. Wait for the oil to cool down before changing it. When draining the oil, do not remove drain plug. Container to catch drained oil Min. 27 L (7.1 gal) Refill capacity 27 L (7.1 gal) Tools required Drain hose, filter wrench 1. Remove the cover at the left side of engine crankcase guard. Set container to catch the oil under the drain plug. 2. Through opening, remove plug (2) at bottom of drain plug (1). In- stall a drain hose (3) of sufficient length to valve.
Loosen drain valve (4) slowly to avoid getting oil on yourself, and drain the oil into the catch container. Check the drained oil, and if there are excessive metal particles or foreign material, please contact your distributor. D87E-2 D87P-2 3-45