Komatsu — CLEAN AIR CLEANER ELEMENTS

MAINTENANCE 3 WHEN REQUIRED 3 CLEAN AIR CLEANER ELEMENTS Remark Whenever the service light comes on, check the air cleaner elements. The audio alarm will not sound. 3 General This machine is equipped with a dry type air cleaner with replaceable filter elements. The air cleaner has two filter elements, a outer and a in- ner. The outer element can be cleaned for a limited number of times be- fore replacement is necessary, however, the inner element must be replaced when plugged. Detailed service procedures for this air cleaner are covered in the following text. 3 Precautions As a precaution against dirt entering the engine: 1.

Cleaner Body Make sure all the air cleaner connections and the turbocharger mounting gaskets are in good condition and all joints and connec- tions are tight. 2. Inner Filter Element 3. Retainer Nut Never operate the engine unless a filter element is in place and the filter end cover o-ring is installed. 4. Seal Washer 5. Outer Filter Element Never remove the element from the air cleaner while the engine is running. 6. Wing Nut 3 Outer Filter Element SERVICE 7. Seal Washer The air cleaner outer element must be serviced whenever indicated by the air cleaner filter service light, see “AIR CLEANER SERVICE LIGHT” on page 2-10.

After servicing the outer element, if the air cleaner filter service light continues to operate, check the air inlet screen or precleaner tubes for obstructions. If service light remains illuminated, replace the inner ele- ment. After servicing the outer element and replacing the inner element, if the service light continues to operate, replace the outer element too. The outer element can be cleaned with compressed air. Remark A outer filter element must be replaced after six cleanings. Remark After cleaning, if an element is to be stored for later use, place it in a plastic bag and store in an element ship- ping container to protect against dirt and damage. D87E-2 D87P-2 3-65