MAINTENANCE 3 TRUNNION HARDWARE Check the torque of the trunnion cap bolts (1), qty. 4, and trunnion plate mounting bolts (2), qty.16. Trunnion hardware 1050 N•m (775 lbf ft) 3 CUTTING EDGE AND END BIT WEAR It is dangerous if the work equipment moves by mistake when the cut- ting edges and end bits are being reversed or replaced. Set the work equipment in a stable condition, then stop the engine. 1. Raise the blade to a proper height and apply a block to the blade frame so as to prevent the blade from falling. 2. Measure the wear of the end bit and cutting edge in accordance with the wear standards given below. Wear Standards Unit: mm (in) 3.
If the cutting edge and the end bit on both sides are worn out, re- place with new one. 4. If it has been worn out up to the fitting surface, repair the fitting surface and then reverse or replace. 5. Remove the cutting edge and the end bit and clean the mounting surface. 6. Reverse or replace the cutting edge and the end bit when worn out. Plow bolt nuts 725 N•m (535 lbf ft) 7. If bolt (1) and nut (2) are damaged, replace them with new ones at the same time. 3-82 D87E-2 D87P-2 Item Judgement standard No.
Measurement point Standard dimension Repair limit 1 Height of cutting edge 254 (10) 213 (8.4) 2 Outer height of end bit 295 (11.6) 211 (8.3) 3 Inner height of end bit 254 (10) 211 (8.3) 4 Width of end bit 450 (17.7) 375 (14.7)