OPERATION 2 Check Decelerator Pedal Travel 1. Measure the distance ( A ) from pedal full height to stop bolt posi- tion, at center of pedal, 53 mm (2.1 in) at 850 ± 50 rpm at stop bolt. 2. If not within these criteria consult your distributor. 2 Check Oil Level in Hydraulic Tank, Add Oil Pressurized Reservoir. When removing the oil filler cap, oil may spurt out, so stop the engine and wait for the oil temperature to go down then turn the cap slowly to release the internal pressure before removing the cap. 1. Check the hydraulic oil level in the tank at the sight gauge. The proper level is: When cold: At bottom of sight gauge When hot:. . . . . . . . . . . . . . . . . . . . . . . . . .
At center of sight gauge 2. Remove the filler cap and add oil to the proper level. Install filler cap. For details of locking cap, see “LOCKING CAP” on page 2-29. For details of the oil to use, see “USE OF FUEL, COOLANT AND LUBRICANTS” on page 3-7. 2 Check Electrical Wiring If a circuit breaker opens frequently, or there are traces of short circuit- ing in the electric wiring, always locate and repair the cause. Check for damage of the circuit breakers and any sign of disconnection or short circuit in the electric wiring. Check also for loose terminals and tighten any loose parts. Check the following points carefully. Batteries Starting Motor Alternator 2-36 D87E-2 D87P-2